65
DX SERIES
TEMPERATURE CONTROLLER
TEMPERATURECONTROLLER
3
Theactionforeachalarmbecomesasfollows:
(▲:Set-value(SV)▵:Alarmset-value)
① If a measured value exceeds the high setting range
limitduetoupscale,etc.,measured-valuedisplaystarts
flashing.
Further,ifitexceedsthehighinputdisplayrangelimit,
themeasured-value(PV)displayunitflashesoverscale
display
「“”」
② Ifameasured-valuebecomesbelowthelowsetting
rangelimitduetodownscale,etc.,measured-value
displaystartsflashing.
Further,ifitbecomesbelowthelowinputdisplay
rangelimit,themeasured-value(PV)displayunit
flashesunder-scaledisplay
「“”」
·After power is applied, the low alarm is turned on
during the temperature rises. If this is not desired, the
low alarm can be suspended after power is applied until
the temperatre goes out of the alarm setting range by
addingtheholdfunction.(Fig.2)
As shown in the following diagram, each of the power,
input, MCU, and output blocks of the DX9 is mutually
isolated.
(1)SettheDipswitchontheinnerPCBtoINITIALset.
(2)Turnonthepower,then displaysontheProcess
Valuedisplayunit(PV),whichisinthestateofinitial
setting.
(3)Pushthemodekey,thentheParameterswillbe
changedasfollows:
✽ BandalarmoperatesonlyALHrelay.